Focal plane mechanical model (SH + UMN); 1/f; temperature stability; detailed cryogenic model;
Precession Speed (Kris, Jacques)
TDM/FDM noise comparisons (Karl, Roger)
Plots of ratio of FDM to TDM noise. Ratios are NEP^2 (left) and NEP (right)
Largest difference is NEP_tot_FDM / NEP_tot_TDM = 1.02. Or ratio of squares, (NEP_tot_FDM / NEP_tot_TDM)^2 = 1.03
Notes
Workshop Follow Up Items
issues of mechanical model: focal plane weight, needs to be revisited and a more realistic model in a few weeks. Heat sinks, mounts etc.
Toki will provide PB focal plane module
1/f
a number of discussions need to be tighten together
temperature stability of ADR, Hannes asked to what extend spikes of T affect responsivity
we know the magnitude of T spikes; should be straightforward
we don’t have complete cryogenic model, temperature loading is AI for Shaul and jPL
Precession
Jacques proposed slow precession; because the scan by scan is closer together, you can make full sky; harder to make continuous map with fast precession
Kris prefers fast precesson
TDM and FDM
We have been assuming sensitivities on FDM coming up from Matt and Franky, but the baseline (physical layout) is TDM
Karl's investigation
most recent TDM number from Roger
photon and phonon calculations between Karl and Roger agree within 1%.
ratio of total NEP squared, largest 3%
basically FDM is higher by 2-3% level.
Toki: readout noise is function of bolo normal resistance; TDM ~10 ohms, FDM ~1 ohm; TDM higher because it needs to compensate high current noise
Conclusion: same. the numbers we had from FDM are fine.