Go to the U of M home page
School of Physics & Astronomy
Probe Mission Study Wiki
imagerteleconnotes20170911

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
imagerteleconnotes20170911 [2017/09/11 12:21] – created kyoungimagerteleconnotes20170911 [2017/09/19 13:51] (current) hanany
Line 1: Line 1:
 ====== Telecon 20170911 ====== ====== Telecon 20170911 ======
 +
 +Attending: Al, Shaul, Amy, Brad, Julian, Brian, Roger, Bill, Jacques, Jeff \\
  
 __Agenda:__  __Agenda:__ 
-  * White noise and focal plane model (Karl) +  * New Permanent Telecon Time: Tuesday 2 pm 
-    * Focal plane size comparison (Qi) +  * White noise and focal plane model {{::pico_noise_open_v_crossed_20170911.pdf|Noise model status}}  (Karl) 
-  * 1/f and TDM readout noise (Roger, Jeff) +    * Focal plane size comparison {{:fov_comparison_09112017.pdf|}} (Qi)  
-  Scan Angles (Kris) +  * White noise comparison; 1/f noise (Roger, Jeff) 
 +    TDM noise :{{::Noise_for_CMB_Probe_v2.pdf|TDM noise Study}} 
 +    * 1/f noise summary : {{::flicker_noise_CMB_probe.pdf| 1/f noise Study}}
  
 __Notes:__ __Notes:__
- Attending: Shaul, Amy, Brian, Kris, Julian, Karl, Qi, Brad, Roger, Jacques, Bill 
  
 +
 +New telecon time.  **Tuesdays 2 pm CDT** starting 9/19.
 +
 +Noise model (Karl)
 +  * Added multichroic pixels
 +    * stop illumination changes with frequency
 +    * Comments:
 +      * **A/I** should set lowest band at 25 dB to be conservative.
 +      * illuminations, diffraction, spillover may need study with GRASP.
 +        * Amy can look for person or software access at JPL. **A/I**: pending discussion with Shaul.
 +  * 100 mK bath temperature added.
 +    * effects low frequencies where phonon noise was dominate at 100 mK bath.
 +  * Single detector NET, Open performs better, particularly at high frequency.
 +  * DLFOV calculated.
 +    * in F*lambda units, crossed diameter is 2x open diameter.
 +    * pixels numbers added which satisfy DLFOV requirements.  Hex packing assumed
 +  * Final polarization weights are similar
 +    * crossed is 0-20% better at most bands.
 +    * open 5% better at only 3 bands.
 +  * Discussion:
 +    * Since roughly equal sensitivity open is probably preferred as focal plane is smaller, fewer detectors, less massive, easier to cool, overall cheaper.  Also lower sidelobes.
 +    * may need to consider diffraction pattern on primary of open.  Does primary need to be oversize?  How much?  A GRASP calculation could be done.
 +
 +Focal plane sizes (Qi)
 +  * Past report said DLFOV for Open/Crossed ~ 75%.  This was stop at primary.
 +  * DLFOV reduced for stop between primary and secondary on open dragone.
 +  * Key points:
 +    * stop location matters and reduces DLFOV.
 +    * results consistent with and explain focal plane sizes in noise presentation.
 +
 +1/f noise and TDM (Roger)
 +  * presentation tied up in JPL release procedure.  Should be shared with 1 week.
 +  * brief summary of work done:
 +    * TDM version of white noise calc in rough agreement with UMN numbers.
 +    * Likely to need 100 mK bath temperature just so bolometers are build-able.  Need a very low G and low T_bath helps achieve this.
 +    * little to no 1/f input from readout developers yet.
 +    * total instrument 1/f compiled from various deployed sources
 +    * how low has been achieved?  Unclear, most experiments use modulators or focus on higher l science.
 +    * Comments: 
 +      * SPIDER has a non-scanning data set which can be examined for 1/f levels. **A/I** Roger to follow-up.
 +      * Niemack may have data on TDM showing 10 mHz 1/f knee.
 +      * will the community doubt 1/f knee as low as needed is possible?  This is a critical component.
 +      * what 1/f knee is needed?  if 1 RPM need 16 mHz. 
 +      * 1 RPM is fast.  Past experiments are 0.5-1 RPM.
 +      * Large broadband HWP is not possible.  Need to address/understand 1/f.
 +      * (Jacques) 1/f not terrible problem if uncorrelated.  only reduces low l sensitivity.
 +        * Gain changes and temperature stability are large problems.
 +      * (Julian) making single detector maps is useful in dealing with 1/f, i.e. scan stratagey matters.
 +        * Has pipeline to do large scale simulations.  "Space is easy."
imagerteleconnotes20170911.1505150479.txt.gz · Last modified: 2017/09/11 12:21 by kyoung