====== Telecon 20180509 ====== | ====== Telecon 20180509 ====== | ||
- | Attending: | + | Attending: |
Notes by : Qi | Notes by : Qi | ||
Line 8: | Line 8: | ||
* Workshop Follow Up Items | * Workshop Follow Up Items | ||
- | * Focal plane mechanical model (SH + UMN) | + | * Focal plane mechanical model (SH + UMN); 1/f; temperature stability; detailed cryogenic model; |
* Precession Speed (Kris, Jacques) | * Precession Speed (Kris, Jacques) | ||
* TDM/FDM noise comparisons (Karl, Roger) | * TDM/FDM noise comparisons (Karl, Roger) | ||
* Plots of ratio of FDM to TDM noise. | * Plots of ratio of FDM to TDM noise. | ||
* {{:: | * {{:: | ||
- | * Largest difference is NEP_FDM | + | * Largest difference is NEP_tot_FDM |
| | ||
=== Notes === | === Notes === | ||
+ | |||
+ | * Workshop Follow Up Items | ||
+ | * issues of mechanical model: focal plane weight, needs to be revisited and a more realistic model in a few weeks. Heat sinks, mounts etc. | ||
+ | * **Toki will provide PB focal plane module** | ||
+ | * 1/f | ||
+ | * a number of discussions need to be tighten together | ||
+ | * temperature stability of ADR, Hannes asked to what extend spikes of T affect responsivity | ||
+ | * we know the magnitude of T spikes; should be straightforward | ||
+ | * we don’t have complete cryogenic model, temperature loading is **AI for Shaul and jPL** | ||
+ | * Precession | ||
+ | * Jacques proposed slow precession; because the scan by scan is closer together, you can make full sky; harder to make continuous map with fast precession | ||
+ | * Kris prefers fast precesson | ||
+ | * TDM and FDM | ||
+ | * We have been assuming sensitivities on FDM coming up from Matt and Franky, but the baseline (physical layout) is TDM | ||
+ | * Karl's investigation | ||
+ | * most recent TDM number from Roger | ||
+ | * photon and phonon calculations between Karl and Roger agree within 1%. | ||
+ | * ratio of total NEP squared, largest 3% | ||
+ | * basically FDM is higher by 2-3% level. | ||
+ | * Toki: readout noise is function of bolo normal resistance; TDM ~10 ohms, FDM ~1 ohm; TDM higher because it needs to compensate high current noise | ||
+ | * **Conclusion: | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ |