====== Telecon 20180523 ====== | ====== Telecon 20180523 ====== | ||
- | Attending: Al, Peter, Tom, Roger, Shaul, Qi | + | Attending: Al, Peter, Tom, Roger, Jacques, Shaul, Qi |
Notes by : Qi | Notes by : Qi | ||
Line 9: | Line 9: | ||
* Temperature Stability and effects on responsivity variations | * Temperature Stability and effects on responsivity variations | ||
* {{:: | * {{:: | ||
- | * {{:: | + | * {{:: |
=== Notes === | === Notes === | ||
Line 60: | Line 60: | ||
* key question: given responsivity model, what would 20 uK change do? | * key question: given responsivity model, what would 20 uK change do? | ||
* **Peter to send raw data of the plot (AI)** | * **Peter to send raw data of the plot (AI)** | ||
- | * **Roger volunteers to take charge of this (AI)** | + | * **Roger volunteers to take charge of this, calculate equivelent signal from this fluctuation |
+ | * Shaul: can affect responsivity, | ||
+ | * Jacques: how 3K will be modulated; on ground, noise from all sorts of things are dominant, but in space, this source could be dominant in fluctuation | ||
+ | * T_focalplane and T_ADR | ||
+ | * time constant C/G: focalplane ~30 kg, C is not hard to estimate, but G may be. **Ask Chris Payne to estimate (AI)**. | ||
+ | * Peter: two different time constants, internal of arrays and between ADR and system. Internal time constant of array is also important. | ||
+ | * Planck active T control | ||
+ | * Jacque: Very long time constant, the fluctuation from dilution does not transfer to focal plane; most fluctuations were from cosmic rays | ||
+ | * Shaul: why was active control still useful if time constant was large? **Check with Brandon (AI)** | ||
+ | * The plot is from 4-stage, 4k to low T; 5-stage should outperform with 1K | ||
+ | * Shaul: 1K stage would have its own fluctuation | ||
+ | * Peter: ASTRO-H lab tests with full space instruments, | ||
+ | * did not do in-space test due to computation limit on board | ||
+ | |||
+ | Noise/band Figure | ||
+ | * Jacques: this one is mostly wrong, no need to discuss. A lot things have been fixed. | ||
+ | * Jacques sends a new figure for Shaul to present. Units are consistent between bands and signals. | ||
+ | * Synchrotron not completely clear | ||
+ | * BB dominated by lensing | ||
+ | * Shaul: six dark blue bands are wrong, should be three | ||
+ | * CO lines | ||
+ | * Current units are for broader community, who do not understand uK. | ||
+ | |||
+ | |||
+ | Shaul will be gone for next 3 weeks until June 18th. After Shaul comes back, report writing mode. | ||
+ | |||
+ | |||