Go to the U of M home page
School of Physics & Astronomy
Probe Mission Study Wiki

User Tools


systematicswg:telecons:2018-07-02:start

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
systematicswg:telecons:2018-07-02:start [2018/07/02 12:00] – created hananysystematicswg:telecons:2018-07-02:start [2018/07/09 11:39] (current) bcrill
Line 6: Line 6:
  
 __E->B Coupling__ \\ __E->B Coupling__ \\
-  * Eric [[http://example.com|posted analysis of beams that Karl sent]]. These are two orthogonal detectors at the center of the focal plane. +  * Eric [[https://zzz.physics.umn.edu/ipsig/beams_and_cl_1|posted analysis of beams that Karl sent]]. These are two orthogonal detectors at the center of the focal plane. 
   * He finds that, as expected, there is no Q->U coupling and no E->B coupling. So far all looks good, as expected.    * He finds that, as expected, there is no Q->U coupling and no E->B coupling. So far all looks good, as expected. 
   * Next step: do the same for an off-axis beam.    * Next step: do the same for an off-axis beam. 
Line 13: Line 13:
   * Kris+Jacques note that these simulations do not include sampling and time constant effects. SH says this is a second priority.    * Kris+Jacques note that these simulations do not include sampling and time constant effects. SH says this is a second priority. 
   * Kris: what do the GRASP simulations include? SH: two reflectors and a stop. Don't expect shields to affect main lobe Q->U coupling. They should affect the far sidelobes.    * Kris: what do the GRASP simulations include? SH: two reflectors and a stop. Don't expect shields to affect main lobe Q->U coupling. They should affect the far sidelobes. 
-  *  + 
-  *  +__Far Sidelobes__ \\ 
 +  As far as Shaul knows, Karl provided far sidelobes to Andrea/Julian. What is the status?  
 +  * **SH will check with Andrea/Julian** 
 + 
 +__Map Simulations__ \\ 
 +  * Andrea is rerunning the map simulations 
 +  * Kris says that 2 year simulations is less useful than 2 independent 1-year simulations. He wants to check map differences. **SH will relay** 
 +  * We also discussed two different goals: 4 detector maps with single detector sensitivity, which will be useful for assessing calibration uncertainties; and, separately, full band sensitivity, which is useful for assessing band sensitivity to CMB.  Kris advocates for having both. **SH will relay** 
systematicswg/telecons/2018-07-02/start.1530550857.txt.gz · Last modified: 2018/07/02 12:00 by hanany