dm_task_force:dec19-11 [2012/02/01 18:28] – [Getting on the same page] chao.zhangdm_task_force:dec19-11 [2012/02/29 09:52] (current) prisca
Line 28: Line 28:
 Fill these out by referring to the method. Fill out numbers and put links to spectra.  Templates are included for the first few entries. Please replace with the correct numbers.   Fill these out by referring to the method. Fill out numbers and put links to spectra.  Templates are included for the first few entries. Please replace with the correct numbers.  
 == Muons per sec per sq meter hitting the top of the water tank (downward) + spectrum if available == == Muons per sec per sq meter hitting the top of the water tank (downward) + spectrum if available ==
-    * 4.4 E-5 (File 1 on LZ geometry - Angie) Explicitly tied to M&H rate. {{:dm_task_force:file.pdf|KE Spectrum}} +    * 4.4 E-5 (File 1 on LZ geometry - Angie) Explicitly tied to M&H rate. 
     * 4.4 E-5 (Method A - Monica)  Uses M&H muon flux rate at Homestake.     * 4.4 E-5 (Method A - Monica)  Uses M&H muon flux rate at Homestake.
     * 6.46 E-5 (Method C - Chao) Deduced by MUSUN+GEANT4     * 6.46 E-5 (Method C - Chao) Deduced by MUSUN+GEANT4
Line 37: Line 37:
 == Neutrons (with KE > 100 KeV) per sec per sq meter hitting the top of the water tank (downward) + spectrum (all energies) == == Neutrons (with KE > 100 KeV) per sec per sq meter hitting the top of the water tank (downward) + spectrum (all energies) ==
     * 1.9 E -6 (File 1 on LZ geometry - Angie)  {{dm_task_force:geodmwithluxnspectrum.png?50 | spectrum }}     * 1.9 E -6 (File 1 on LZ geometry - Angie)  {{dm_task_force:geodmwithluxnspectrum.png?50 | spectrum }}
-    * 5.E-6 (Method A - Monica)  Uses M&H muon-induced neutron flux rate at Homestake.+    * 1.E-6 (Method A - Monica)  Uses M&H muon-induced neutron flux rate at Homestake and accounts for top and bottom of the water tank.
     * 2.91 E-6 (Method C - Chao) MUSUN+GEANT4     * 2.91 E-6 (Method C - Chao) MUSUN+GEANT4
 == Neutrons (with KE > 100 KeV) per sec per sq meter hitting all outer walls of the tank (from out to in) +spectrum (all energies) ==  == Neutrons (with KE > 100 KeV) per sec per sq meter hitting all outer walls of the tank (from out to in) +spectrum (all energies) == 
     * 2.4 E -6  (File 1 on LZ geometry - Angie) {{dm_task_force:geodmwithluxnspectrumAll.png?50 | spectrum }}      * 2.4 E -6  (File 1 on LZ geometry - Angie) {{dm_task_force:geodmwithluxnspectrumAll.png?50 | spectrum }} 
-    * 5.E-6 (Method A - Monica)  Uses M&H muon-induced neutron flux rate at Homestake.+    * 3.E-6 (Method A - Monica)  Uses M&H muon-induced neutron flux rate at Homestake.
     * 1.13 E-6 (Method C - Chao) MUSUN+GEANT4     * 1.13 E-6 (Method C - Chao) MUSUN+GEANT4
 == Neutrons (with KE > 100 KeV) per sec per sq meter entering detector volume + spectrum == == Neutrons (with KE > 100 KeV) per sec per sq meter entering detector volume + spectrum ==