-====== Material Purification and Assay ====== 
- 
- 
-  - Description/Name: Electroforming Copper 
-  - Planned use (be specific): Cryostat and Inner Shield 
-     - Primary function: Electroforming copper at the 4850-ft level 
-     - Temporary and permanent storage: raw coper materials, electroformed copper, chemical materials 
-     - Sample and detector handling: Acid, electrodes, chemical stuff 
-     - Jigs, fixtures, scaffolds, etc. necessary:  Lab fixtures: light-duty; power, lights, laboratory casework, communications (phone/computer), standard wall coverings, 50 kW of power, eye washing machine, bath 
-     - E & O activities: daily (emergency 24/7), material transport UG, Chemical transport, Utilities: air, water, heat/cooling, light, communications, commercial drains, 18-M water, chemical drain/disposal path, compressed air, humidity control, snorkel  
-  - Occupancy:  
-     - Steady: 2 persons 
-     - Peak: 10 persons 
-  - Adjacencies (list/distance): 2 meters 
-  - Space size (gsf and/or WxLxH): 4m x 20 m x 3m 
-  - Experiment Systems: Electroforming copper, ventilation of 50 cfm for each electroforming bath, general ventilation, 4 nitrogen generators, 4 hydrogen generators 
-  - Shielding: No 
-  - Floor load (PSF): General 
-  - Material handling (cranes, etc.) Chemicals, water baths, daily (emergency 24/7), material transport UG, Chemical transport 
-  - Finishes (walls/floor/ceiling): General 
-  - Casework: 
-  - Storage: Chemical cabinet 
-  - Furniture/Fixtures/Equipment (non-experiment): tables, water bath, eye washing machine 
-  - Mechanical: 
-     - Environmental conditions: Radon free air,  
-     - Clean class: 2000, 100 for enclose area 
-     - Ventilation: 50 cfm 
-     - Exhaust: 50 cfm 
-     - Plumbing (domestic, waste, systems): water  
-     - Fire Suppression: 
-     - Building Management System: hoods, snorkels (for e-form bath ventilation), tables, chairs, chemical storage cabinets, storage cabinets, safety shower and eyewash, lot of windows. 
-     - Fume hoods: 1 (ea 4x5ft^2=20ft^2: 20ft^2) - hoods 
-     - Chilled water: 
-     - Other:  
-  - Electrical: 
-     - Power (clean and dirty): 50 KW 
-     - Lighting: general 
-     - Low Voltage/Data/Communication:  
-     - Fire Detection/Alarm: 
-     - Other:  