Go to the U of M home page
School of Physics & Astronomy
Assay and Acquisition of Radiopure Materials

User Tools


vetoshield:gas

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
vetoshield:gas [2015/07/16 17:06] – [References and Additional Information] jeffvetoshield:gas [2015/07/29 13:15] (current) – [References and Additional Information] jeff
Line 220: Line 220:
 {{:vetoshield:gasrackbackupv2015-7-1.zip|}} {{:vetoshield:gasrackbackupv2015-7-1.zip|}}
  
-The main VI (gas_rack_controller.vi) is in the folder "Controller and SubVIs" folder along with the SubVIs it directly calls. A copy of the exectuable along with the helper files is alongside these files in another folder called "builds". Some of the SubVIs outside the "Controller and SubVIs" folder are also needed while some are just testing VIs.+The main VI (gas_rack_controller.vi) is in the folder "Controller and SubVIs" folder along with the SubVIs it directly calls. A copy of the exectuable along with the helper files are inside the folder called "builds". Some of the SubVIs outside the "Controller and SubVIs" folder are also needed. There are some unused VIs
 + 
 +The LabVIEW code was written in LabVIEW 2012. If using the .exe instead of the VI, LabVIEW itself does not need to be installed but you must have the LabVIEW run-time engine (version 2012f3) and DAQmx 9.4.0 installed.
  
 Also included is the firmware code to program the CPLD located on the control board located inside the blue panel: Also included is the firmware code to program the CPLD located on the control board located inside the blue panel:
Line 250: Line 252:
 {{:vetoshield:mixer_control_board.jpg?700}} {{:vetoshield:mixer_control_board.jpg?700}}
  
-===Programming control=== +The CPLD configuration file is posted at the end of this manual along with the software written in LabVIEW.
- +
-[Joe is currently in the process of finding a copy of the CPLD programming to post right here. Upon repetitive failure to find the copy, this subsection will be omitted.]+
  
 ===Software Control=== ===Software Control===
Line 356: Line 356:
 ====References and Additional Information ==== ====References and Additional Information ====
  
-Here is a backup containing the VIs and the configuration file needed to run the gas mixer. The top level VI is called "Mixer Control 3.vi":+backup of the Gas Mixer folder containing necessary software needed to run the controller: 
 + 
 +{{:vetoshield:gas_mixer_2015-7-15.zip|}} 
 + 
 + 
 +The main VI (mixer_controllerYYYY-MM-DD.vi) is included along with the necessary SubVIs. A copy of the pre-compiled executable along with a few helper files is alongside these files in another folder called “builds”. Also included are the necessary auxiliary files the controller needs access to which are the three log text files it writes to plus the config file "gas mixer.iniand the mail list it reads from.  
 + 
 +The LabVIEW code was lasted edited in LabVIEW 2012. If using the .exe instead of the VI, LabVIEW itself does not need to be installed but you must have the LabVIEW run-time engine (version 2012f3) and DAQmx 9.5.1 installed. 
 + 
 +The CPLD firmware is also included: 
 + 
 +{{:vetoshield:gas_mixer.zip|}} 
 + 
 +There is an up-to-date version of the .jed configuration file. The source code included is not the most recent version but is the only version I have been able to find. 
 + 
 + 
  
-{{:vetoshield:mixer_backup12-13-12.zip|}} 
  
-For additional information on the gas mixing system try Joe Pastika at past0035@umn.edu. 
vetoshield/gas.1437084374.txt.gz · Last modified: 2015/07/16 17:06 by jeff