Go to the U of M home page
School of Physics & Astronomy
Probe Mission Study Wiki
imagerteleconnotes20171003

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
imagerteleconnotes20171003 [2017/10/03 12:42] – created hananyimagerteleconnotes20171003 [2017/10/10 12:55] (current) hanany
Line 1: Line 1:
-====== Telecon 20170926 ======+====== Telecon 20171003 ======
  
-Attending:  \\+Attending:  Al, Roger, Jacques, Jeff F., Shaul, Karl, Qi, Ranajoy, Brian \\
  
 __Agenda:__  __Agenda:__ 
  
-   * Imager + Spectrometer (Karl) +   * Imager + Spectrometer (Karl) {{:pico_and_pixie_20171003.pdf|Spectrometer Slides}} 
-   * Focal plane + noise model (Karl) +   * Focal plane + noise model (Karl) {{:pico_fdm_noise_model_status_20171003.pdf|Noise model slides}} 
-   * optical system (Qi)+   * optical system (Qi) {{::crossdragone_d100cm_f4.5_fov10deg_10032017.pdf|}}
    * Scan parameters (Shaul (for Kris))    * Scan parameters (Shaul (for Kris))
  
 __Notes:__ __Notes:__
 +
 +Imager + Spectrometer (Karl)
 +  * mini-PIXIE, 20 cm mirrors, 10x38x48 FTS
 +    * Same boresight angle
 +    * Share same cooling system
 +  * mass of mini-PIXIE, ~20 kg in total, barrel contributes most of it.
 +    * detector assembly is  < 1kg
 +  * Imager focal plane mass: not known yet.  **A/I** Brian to ping Roger.
 +  * with Open Dragone
 +    * same boresight as Imager, although not necessary
 +    * quite small, fits easily
 +  * with Cross Dragone
 +    * boresights don't match, but scan pattern does (beta is same in both cases)
 +    * Al: it’s okay. There will be some time delay between imager and spectrometer scans, but it does not matter much.
 +  * Boresight and spin axis
 +    * It’s not required to have boresight along the spin axis. PIXIE did plan to align with spin axis,allows fitting of Q/U of each pixel before moving to next pixel.
 +      * It’s okay to not do this. The current main driver is the sky coverage.
 +  * FTS box is not required to be with optical tubes, it can be anywhere as long as an optical path exists.
 +    * The detectors can even be on the Imager focal plane.
 +  * Tradeoffs: 
 +    * question of cost, might limit imager size
 +      * Current primary costs: cooling,  telescope,  readout, and detectors
 +      *  marginal costs when increasing
 +  * Aside:
 +    * Check Open Dragone fit, to see if there is conflict between mirrors and cone.  **A/I** UMN to check.
 +    * structural issues with support for mirrors?
 +      * Brian: JPL is working on this question.
 +
 +Noise Model (Karl)
 +  * Biggest change: safety factor → 2
 +  * Squid is the largest contribution
 +     * Using 3.5 pA/rt(Hz).  **A/I** Karl checking with Hannes at NIST about proper number to quote.
 +  * Roger: all these numbers are fine.
 +  * Cross check between Karl and Roger.  noise matches except for:
 +    * bunching noise, a factor of 2
 +    * bunching noise does not contribute too much, ~15%; all other are same
 +    * **A/I** Karl, track down 2 in bunching noise.  Possibly polarization related.
 +  * Richard’s correction on Coma
 +    * more detectors at high frequencies, for both Open and Cross Dragone
 +    * can weight CMB frequencies more heavily.
 +  * Can optimize edge taper
 +    * including correlated photon bunching noise from CMB (correctly) and mirrors (incorrectly, but with factor of 2)
 +      * Next step: Karl to implement full correct calculation for mirrors.
 +    * best mapping speed is near 2 F lambda.  Current Open Dragone pixels are at 2 F lambda.
 + 
 +Optics (Qi)
 +  * New cross-dragone with +/- 10 deg FOV
 +    * f/4.5, 1m aperture, requires deployable shields.
 +    * deployable shields should be V-grooves as well. leave design to thermal engineers. Just put place-holder in current model
 +  * both cross dragones' focal planes view sky after 1 reflection off tertiary
 +  * total sensitivity is better than Open dragone (baseline)
 +    * assumes full telescope is 4 K
 +    * also number of detectors is larger.  3k for Open, 7k and 11k for new crossed designs.
 +  * How does larger f-number give better sensitivity?  Opposite what is normally said.  From CORE, increasing f-number gave no benefit since pixels grew at same rate focal plane grew.
 +    * **A/I** Karl/Qi to sort out scaling of focal plane with f-number.
 +
 +Scan delayed to next week.
 +
  
imagerteleconnotes20171003.1507052561.txt.gz · Last modified: 2017/10/03 12:42 by hanany