Go to the U of M home page
School of Physics & Astronomy
Probe Mission Study Wiki

User Tools


imagerteleconnotes20171205

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
imagerteleconnotes20171205 [2017/12/05 13:42] hananyimagerteleconnotes20171205 [2017/12/05 14:47] (current) kyoung
Line 1: Line 1:
 ====== Telecon 20171205 ====== ====== Telecon 20171205 ======
  
-Attending:  +Attending:  Kris, Tom, Roger, Qi, Karl, Shaul, Brian
  
 Notes by : Karl \\ Notes by : Karl \\
Line 9: Line 9:
      * {{::extension_shields.pdf|Last Week's Presentation}}      * {{::extension_shields.pdf|Last Week's Presentation}}
      * {{::171130_pico_iso-front.jpg?25|New approach}}      * {{::171130_pico_iso-front.jpg?25|New approach}}
-   * Data Rate (Shaul) +   * Focal plane V3.0 (Karl) 
-   * Focal plane V3.0 (Karl?)+     * {{::sensitivity_updates_20171205.pdf|V3.0 status}}
    * Update from JPL     * Update from JPL 
-   +
 === Notes:=== === Notes:===
 +
 +New sun shields, new alpha/beta? (JPL, UMN)
 +  * high angle tulip shields.
 +  * primary protected.
 +  * possible adjustments to alpha 30 or 35
 +  
 +Focal plane V3.0 (Karl)
 +  * 40K primary and 0.07% emissivity.
 +  * a 10% margin is included in these numbers given to the science team, just so they see less fluctuations.
 +  * Shaul: option to increase FP size and number bolos by 2x.  Keep this in mind.
 +    * Limits currently are data rate, see main imager wiki: posting/datavolume
 +      * 15k bolos give 3 Tb/day but DSN for 4 hours is 2 Tb/day
 +    * Kris: this is a stiff constraint for 10 yrs in future. Planck saw same type of limits evaporate during their planning.
 +
 +
 +Update from JPL
 +  * Roger: Wiring and thermal load w/ Chris Paine.  TDM and FDM.
 +    * FDM, has few wires to mK.  More complicated warm readout. (Shaul: more power, yes. not necessarily more complicated. )
 +      * Power usage 15k bolos -- 375 W for FDM
 +    * TDM, fewer wires. simpler warm readout
 +    * calculating heat load on mK from heat conduction and detector dissipation.
 +      * dissipation < 1 uW. not a problem.
 +    * wire count
 +      * x64 -- 1850 wires (TDM), with 350 mK buffer stage, few - 50 uW load on mK.
 +      * x128 -- 1140 wires, 3-30 uW load.
 +    * Next step, starting on FDM.
 +    * Peter Day is detector Team X partner.  Typically supportive of aggressive stance.
 +  * Brian: Joelle's model given to thermal analyst
 +    * from him: 
 +      * Just satellite drifting passively: space craft 260 K, primary 31 K.
 +      * Adding heat sources, coolers, etc. to refine numbers.
 +      * Shaul: need inputs to Goddard for ADR design.  Timeline?
 +        * Tom: need this by end of this week.
 +
 +Team X is December 19.
 +
imagerteleconnotes20171205.1512502957.txt.gz · Last modified: 2017/12/05 13:42 by hanany